- There are no more items in your cart
- Shipping Free
- Total €0.00
For ignition MVT Millenium scooters PEUGEOT before 2006 and mopeds PEUGEOT 103, so for ignition references Millenium EXT102 / EXT103 / EXT104 / EXT105 / EXT108 / EXT116
Here is a very practical case, it was invented a few years ago by Mr. Alain GODOU (former boss of AGP and now boss of MVT ignition). This case will allow you many wonders:
1-This case improves and increases the variation (more variable curve).
2-This case will offer you the choice between 3 different ignition curves.
3-This case will allow you to adjust the advance and this without dismantling.
In short, this case will increase the variation of ignition, the number of degrees of offset depending on the minute turns, the ignition will obviously be much more efficient. One ignition curve represents the variation according to the number of revolutions minutes. For example, a torqued engine will require at best a fairly low and torqued curve while a very high-speed engine will require a very pronounced curve. Here you can select the desired curve, 3 curves offer to you, to modify & select it, just enter a combination of numbers (notice and combinations of numbers provided with the piece). Finally, once the curve is selected, you can change the ignition advance (the famous ignition setting). No need for setting pin and tool to modify. Only a combination of numbers! For example, here is the list of combinations and their actions on ignition:
Start by ticking your ignition MVT a key on groove D like DIGITAL. Take care to check your carburation every time you try!
Code 000000= curve MVT 1 and +3° in advance
Code 100000= curve MVT 1 and +2° in advance
Code 110000= curve MVT 1 and +1° in advance
Code 111000= curve MVT 1 and +0° in advance (for example MVT Premium or Digital Direct origin)
Code 111100= curve MVT 1 and -1° in advance
Code 011100= curve MVT 1 and -2° ahead
Code 001100= curve MVT 3 and +3° ahead
Code 000100= curve MVT 3 and +2° ahead
Code 001000= curve MVT 3 and +1° in advance
Code 010000= curve MVT 3 and +0° in advance (such as the MVT Premium or Digital Direct origin)
Code 011000= curve MVT 3 and -1° ahead
Code 010100= curve MVT 3 and -2° ahead
Code 110100= curve MVT 4 and +3° ahead
Code 111110= curve MVT 4 and +2° ahead
Code 110110= curve MVT 4 and +1° in advance
Code 010010= curve MVT 4 and +0° in advance (such as the MVT Premium or Digital Direct origin)
Code 110010= curve MVT 4 and -1° ahead
Code 100010= curve MVT 4 and -2° ahead
Once you have selected the curve the appropriate advance to your engine, take good care to recheck your carburation! This small case will bring even more performance to your engine, if you are well adjusted, the gain is impressive.